Skip to content
xmoo.app

Tool · Electrical

Decibel Calculator

dB to a ratio and back, dBm to watts and volts, dBµV at 50 Ω or 75 Ω, and adding levels – each with the working shown.

dB ↔ ratio

Fill in either field and the tool works out the other.

Level difference
Power ratio
Voltage and current ratio

      

Convert levels: dBm, dBW, dBµV, dBV, dBu

Voltages are RMS values. The impedance links power and voltage (P = V² ÷ R).

dBm
dBW
Power
Voltage (RMS)
dBµV
dBV
dBu

      

Adding levels

Several values, separated by spaces or semicolons. Applies to sources that are unrelated to each other (uncorrelated).

Total level
Above the loudest source

      

What a decibel is

A decibel is not a unit like the volt or the watt but a logarithmic ratio. The bel is the base-10 logarithm of a power ratio, and the decibel is a tenth of a bel. For a power P compared with a reference power P₀:

L = 10 × log(P ÷ P₀) dB

Voltage and current enter the power squared (P = V² ÷ R). So that the same change gives the same number of decibels, they take a factor of 20 – provided both values are across the same impedance:

L = 20 × log(V ÷ V₀) dB

That is why the calculator shows two ratios: 3 dB is just under twice the power (ratio 1.995) but only 1.413 times the voltage. 6 dB is twice the voltage and just over four times the power. 10 dB is ten times the power, 20 dB ten times the voltage. Negative values mean attenuation: −3 dB leaves 50.1 % of the power.

The advantage: gains and losses in a chain are simply added in dB instead of multiplying the ratios.

dBm, dBW, dBµV and friends: levels with a fixed reference

When “dB” carries a reference, it is an absolute level. The number then says how far a value lies above or below that reference:

SymbolReferenceFormulaTypical use
dBW1 W10 × log(P ÷ 1 W)transmitter power
dBm1 mW10 × log(P ÷ 1 mW)radio, Wi-Fi, test equipment
dBµV1 µV20 × log(V ÷ 1 µV)receiver levels, TV and satellite
dBV1 V20 × log(V ÷ 1 V)audio, consumer equipment
dBu0.775 V20 × log(V ÷ 0.775 V)studio and pro audio

The 0.775 V of the dBu is the voltage that dissipates exactly 1 mW in 600 Ω – the old characteristic impedance of telephone lines. Strictly it is √0.6 V ≈ 0.7746 V; the ITU gives 0.775 V, and that is the value the tool uses. The difference is 0.005 dB.

Between power and voltage levels there is always the impedance. From V² = P × R it follows that:

dBµV = dBm + 90 + 10 × log(R ÷ 1 Ω)

At 50 Ω that is dBm + 106.99, at 75 Ω dBm + 108.75. Using “+107” is right at 50 Ω but 1.76 dB out at 75 Ω.

Example 1: how much power reaches the antenna?

A transmitter delivers 100 W and the coax to the antenna has a loss of 2 dB at the operating frequency (example values; the loss per 100 m is in the cable’s data sheet).

  1. 100 W in dBm: 10 × log(100 W ÷ 1 mW) = 10 × log(100,000) = 50 dBm
  2. After the cable: 50 dBm − 2 dB = 48 dBm
  3. Back to watts: 1 mW × 10^(48 ÷ 10) ≈ 63.1 W. The other 36.9 W turn into heat in the cable.

The same with the ratio: 10^(−2 ÷ 10) = 0.631, so 63.1 % of the power arrives. Enter −2 dB in the calculator above and this value appears under “Power ratio”.

Transmitter 100 W Coax −2 dB Antenna ≈ 63.1 W 50 dBm 50 dBm − 2 dB 48 dBm In dB you subtract, in watts you multiply: 100 W × 0.631 ≈ 63.1 W ≈ 36.9 W turn into heat in the cable
Loss as a level calculation: after 2 dB of cable loss, 50 dBm becomes 48 dBm, about 63.1 W. Values from example 1. Own illustration.

Whether that much really arrives at the end of the line is measured with an in-line wattmeter, as built into many SWR meters. It has to be rated for the frequency and the power.

SWR and power meter*

Marked with *: affiliate links. As an Amazon Associate I earn from qualifying purchases.

Example 2: −60 dBm in volts and dBµV

A measuring receiver shows −60 dBm at its 50 Ω input. What voltage is that? These values are in the calculator when the page opens.

  1. Power: P = 1 mW × 10^(−60 ÷ 10) = 10⁻⁹ W = 1 nW
  2. Voltage: V = √(P × R) = √(1 nW × 50 Ω) ≈ 223.6 µV
  3. In dBµV: 20 × log(223.6 µV ÷ 1 µV) ≈ 46.99 dBµV – that is −60 + 106.99.

Example 3: two equally loud sources

Two machines each produce 60 dB. Together that is not 120 dB, because it is the powers that add, not the levels:

  1. 10^(60 ÷ 10) + 10^(60 ÷ 10) = 1,000,000 + 1,000,000 = 2,000,000
  2. 10 × log(2,000,000) ≈ 63.01 dB

So twice the power means +3.01 dB, ten equal sources +10 dB. If one source is 10 dB quieter than the other, it only raises the total by 0.41 dB. This holds for independent sources, such as two machines or two noise sources. Two in-phase signals of the same frequency add differently (up to +6 dB), and signals in antiphase cancel out.

Table: dB to ratio

Level difference and ratio for power and for voltage and current
dBPower ratioVoltage/current ratio
−40 dB0.00010.01
−30 dB0.0010.03162
−20 dB0.010.1
−10 dB0.10.3162
−6 dB0.25120.5012
−3 dB0.50120.7079
−1 dB0.79430.8913
0 dB11
1 dB1.2591.122
3 dB1.9951.413
6 dB3.9811.995
10 dB103.162
20 dB10010
30 dB1,00031.62
40 dB10,000100

Table: dBm to watts and volts

Voltage and dBµV apply at 50 Ω. At 75 Ω the voltage is higher by a factor of √1.5 ≈ 1.22 and the dBµV value by 1.76 dB.

dBm, power, voltage and dBµV at 50 Ω
dBmPowerVoltage at 50 ΩdBµV at 50 Ω
60 dBm1 kW223.6 V166.99 dBµV
50 dBm100 W70.71 V156.99 dBµV
47 dBm50.12 W50.06 V153.99 dBµV
43 dBm19.95 W31.59 V149.99 dBµV
40 dBm10 W22.36 V146.99 dBµV
37 dBm5.012 W15.83 V143.99 dBµV
33 dBm1.995 W9.988 V139.99 dBµV
30 dBm1 W7.071 V136.99 dBµV
27 dBm501.2 mW5.006 V133.99 dBµV
20 dBm100 mW2.236 V126.99 dBµV
10 dBm10 mW707.1 mV116.99 dBµV
0 dBm1 mW223.6 mV106.99 dBµV
−10 dBm100 µW70.71 mV96.99 dBµV
−20 dBm10 µW22.36 mV86.99 dBµV
−30 dBm1 µW7.071 mV76.99 dBµV
−50 dBm10 nW707.1 µV56.99 dBµV
−70 dBm100 pW70.71 µV36.99 dBµV
−90 dBm1 pW7.071 µV16.99 dBµV
−110 dBm10 fW707.1 nV−3.01 dBµV

Limits of this tool

Privacy: the calculator runs entirely in your browser. What you enter is not sent to xmoo.app or anyone else.

Sources

Page last updated: 27 November 2026